Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Oncol ; 18(1): 12, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36658595

RESUMO

OBJECTIVE: The purpose of this study is to verify the correlation between medium and low radiation doses of the pelvic-bone marrow and the incidence of lymphocytic toxicity during concurrent chemoradiotherapy for cervical cancer. MATERIALS AND METHODS: This research included 117 cervical cancer patients, who received concurrent chemoradiotherapy. Radiotherapy included external-beam radiation therapy and brachytherapy. The dosimetry parameters include the Volume receiving 5 Gy (V5), 10 Gy (V10), 20 Gy (V20), 30 Gy (V30), 40 Gy (V40), 50 Gy (V50), and the mean dose (D mean) of the bone marrow. Lymphocytic toxicity was calculated from lowest lymphocytic count after two cycles of concurrent chemotherapy. RESULTS: During concurrent chemoradiotherapy, the incidence of lymphocytic toxicity is 94.88%. The incidence of grade 3-4 toxicity is 68.38%. Multivariate analysis findings show that the dosimetry parameters V5, V10, V20, and V30 are significantly correlated with lymphocytic toxicity. The patients are divided into small-volume subgroups and large-volume subgroups based on the cutoff values. The relative risk of both grade 1-4 and grade 3-4 lymphocytic toxicity is significantly lower in the small-volume subgroups than in the large-volume subgroups (P < 0.05). Kaplan-Meier analysis shows that the incidence of both grade 1-4 and grade 3-4 lymphocytic toxicity of the small-volume subgroups is significantly lower than that of the large-volume subgroups (P < 0.05). CONCLUSION: There is a significant correlation between a medium and low dose of pelvic-bone-marrow radiation and incidence of lymphocytic toxicity. Reducing the volume of medium and low radiation doses could effectively reduce incidence of lymphocytic toxicity.


Assuntos
Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Medula Óssea , Radioterapia de Intensidade Modulada/efeitos adversos , Dosagem Radioterapêutica , Neoplasias do Colo do Útero/radioterapia , Quimiorradioterapia/efeitos adversos , Doses de Radiação
2.
Mol Oncol ; 14(11): 2744-2758, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32688456

RESUMO

Lung cancer has the highest mortality of all cancers worldwide. Epigenetic alterations have emerged as potential biomarkers for early diagnosis of various cancer tissue types. To identify methylation markers for early diagnosis of lung adenocarcinoma, we aimed to integrate genome-wide DNA methylation and gene expression data from The Cancer Genome Atlas. To this end, we first examined the global DNA methylation pattern of lung adenocarcinoma and investigated the relationship between DNA methylation subtypes and clinical features. We then extracted differentially methylated and expressed genes, and adopted feature selection techniques to determine the final methylation markers. The performance of the markers in predicting lung adenocarcinoma was evaluated on three independent datasets from Gene Expression Omnibus. Protein levels of marker genes were validated by immunohistochemistry, and their biological function was further verified in vivo. We identified three novel methylation markers in lung adenocarcinoma including cg08032924, cg14823851, and cg19161124, mapping to CMTM2, TBX4, and DPP6, respectively. Validating these results on three independent datasets indicated that the three markers can achieve extremely high sensitivity and specificity in distinguishing lung adenocarcinoma from normal samples. Immunohistochemistry quantification results confirmed that markers are weakly expressed in human lung adenocarcinoma, and CMTM2 decreased tumor growth of mouse Lewis lung carcinoma in vivo. Overall, our study identified three novel methylation markers in lung adenocarcinoma which may contribute toward an improved diagnosis potentially leading to a better outcome for patients with lung adenocarcinoma.


Assuntos
Adenocarcinoma de Pulmão/genética , Metilação de DNA , Neoplasias Pulmonares/genética , Adenocarcinoma de Pulmão/diagnóstico , Idoso , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/genética , Detecção Precoce de Câncer , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade
3.
Carcinogenesis ; 37(11): 1089-1097, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27559112

RESUMO

Aberrant sialylation has long been correlated with human cancer. Increased ST6 Gal I (ß-galactoside α 2, 6 sialyltransferase) and consequently higher levels of cell-surface α 2, 6 sialylation has been associated with human colorectal cancer (CRC) metastasis. We have extensive circumstantial data that sialylation is connected to cancer metastasis, but we do not understand in detail how sialylation can switch on/off multiple steps in cancer metastasis. To investigate the molecular mechanism underlying the ST6Gal I-mediated metastasis of CRC, we silenced the ST6Gal I gene in a metastatic SW620 CRC cell line (SW620-shST6Gal I) and examined the metastatic behavior of the cells. We found that various hallmarks of metastatic ability were considerably enhanced in ST6Gal 1-depleted SW620 clones, as assessed both in vitro and in vivo . In particular, the metastasis suppressor, KAI1, was down-regulated in ST6Gal I-deficient SW620 clones. This reflected the increased exosome-mediated exportation of KAI1, and was associated with a decrease in the KAI1-mediated inhibition of integrin. These findings indicate that gene silencing of ST6Gal I could enhance metastasis of CRC by down-regulating KAI1 activity and rescuing its negative effects on integrin signaling.

4.
Phys Med ; 31(5): 553-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26048682

RESUMO

PURPOSE: This paper describes the hardware and software characteristics of a 3D optical scanner (P3DS) developed in-house. The P3DS consists of an LED light source, diffuse screen, step motor, CCD camera, and scanner management software with 3D reconstructed software. MATERIALS AND METHOD: We performed optical simulation, 2D and 3D reconstruction image testing, and pre-clinical testing for the P3DS. We developed the optical scanner with three key characteristics in mind. First, we developed a continuous scanning method to expand possible clinical applications. Second, we manufactured a collimator to improve image quality by reducing scattering from the light source. Third, we developed an optical scanner with changeable camera positioning to enable acquisition of optimal images according to the size of the gel dosimeter. RESULTS: We confirmed ray-tracing in P3DS with optic simulation and found that 2D projection and 3D reconstructed images were qualitatively similar to the phantom images. For pre-clinical tests, the dose distribution and profile showed good agreement among RTP, optical CT, and external beam radiotherapy film data for the axial and coronal views. The P3DS has shown that it can scan and reconstruct for evaluation of the gel dosimeter within 1 min. We confirmed that the P3DS system is a useful tool for the measurement of 3D dose distributions for 3D radiation therapy QA. Further experiments are needed to investigate quantitative analysis for 3D dose distribution.


Assuntos
Imageamento Tridimensional/instrumentação , Imagem Óptica/instrumentação , Medicina de Precisão/instrumentação , Doses de Radiação , Radiometria/instrumentação , Desenho de Equipamento , Humanos , Neuroma Acústico/diagnóstico por imagem , Tomografia Computadorizada por Raios X
5.
Med Dosim ; 40(4): 285-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25869936

RESUMO

The purpose of this study is to evaluate the influence of treatment-planning parameters on the quality of treatment plans in tomotherapy and to find the optimized planning parameter combinations when treating patients with prostate cancer under different performances. A total of 3 patients with prostate cancer with Eastern Cooperative Oncology Group (ECOG) performance status of 2 or 3 were included in this study. For each patient, 27 treatment plans were created using a combination of planning parameters (field width of 1, 2.5, and 5cm; pitch of 0.172, 0.287, and 0.43; and modulation factor of 1.8, 3, and 3.5). Then, plans were analyzed using several dosimetrical indices: the prescription isodose to target volume (PITV) ratio, homogeneity index (HI), conformity index (CI), target coverage index (TCI), modified dose HI (MHI), conformity number (CN), and quality factor (QF). Furthermore, dose-volume histogram of critical structures and critical organ scoring index (COSI) were used to analyze organs at risk (OAR) sparing. Interestingly, treatment plans with a field width of 1cm showed more favorable results than others in the planning target volume (PTV) and OAR indices. However, the treatment time of the 1-cm field width was 3 times longer than that of plans with a field width of 5cm. There was no substantial decrease in treatment time when the pitch was increased from 0.172 to 0.43, but the PTV indices were slightly compromised. As expected, field width had the most significant influence on all of the indices including PTV, OAR, and treatment time. For the patients with good performance who can tolerate a longer treatment time, we suggest a field width of 1cm, pitch of 0.172, and modulation factor of 1.8; for the patients with poor performance status, field width of 5cm, pitch of 0.287, and a modulation factor of 3.5 should be considered.


Assuntos
Adenocarcinoma/radioterapia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Idoso , Humanos , Masculino , Medicina de Precisão , Radioterapia de Intensidade Modulada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...